Trung tâm báo cháy 4 vùng UNIPOS FS4000/4

Chat Zalo hoặc Gọi ngay 0984 104 365 để được tư vấn giá tốt!

4.800.000 

Trung tâm báo cháy 4 vùng UNIPOS FS4000/4

– Fire control panel FS4000/4 is designed to operate with conventional automatic fire detectors and manual call points. The panel has outputs provided for external executive devices.

Functional 

– Identification of manual call points.

– Zone dedicated label and Zone dedicated LED indication for fire, fault, disable.

– Detection for removed fire detector.

– Automatic reset of the fault warning condition.

– Logical “AND” scenario for fire detection lines.

– EN54-2 Disabled condition and Test condition per fire detection line and fire alarm line.

– Direct mode (skip delay) function for each fire detection line.

– Test-LED functionality.

– Built-in buzzer for fire and fault condition – one tonal, continuous, can be suppressed.

– Test mode for fire alarm lines.

– Input for remote Reset fires operation.

– 8 types optional scenarios for common fire outputs and fire alarm outputs.

– Optional delay time for fire outputs activation – 1,2,3,4,5,6 or 7 minutes.

– Evacuation condition – available on access level 2.

– Optional zone dedicated relay module FD4201, each relay is common fire output corresponding to the relevant fire detection zone.

Thông số kỹ thuật và tính năng

– Fire alarm lines:

   + Maximum number of fire detectors in a line: 32.

   + Connecting line: two-wire.

   + Maximum resistance of a line: 100Ω.

– Current thresholds for:

   + Fault condition: 0 – 6 mA.

   + Duty mode: 6 – 16 mA.

   + Fire condition: 16 – 80 mA.

   + Short circuit: > 80 mA.

– Monitored outputs for fire condition:

   + Number: 2 pcs.

   + Type: potential, relay with independent control.

   + Electrical characteristics: (19-27.5)VDC/1A.

– Relay outputs for fire condition:

   + Number: 2 pcs.

   + Type: potential-free,1 switching, 1 NO.

   + Electrical characteristics: 3А/125V AC, 3A/30V DC.

– Relay output for fault condition:

   + Number: 1 pcs.

   + Type: potential-free, switching.

   + Electrical characteristics: 3А/125V AC, 3A/30V DC.

– Relay output for fault condition:

   + Number: 1 pcs.

   + Type: none-monitored type activated on short-circuit (from potential free contact).

   + Electrical characteristics: 5 VDC on normal open state/ 0 VDC in activation mode.

– Performance:

   + Control over fire alarm lines and controllable outputs for fault conditions (short circuit and interruption) and automatic reset.

   + Detection of removed fire detector and automatic reset.

   + Identification of manual call points.

   + LED indication for alarm state and emergency.

   + Delay of outputs for fire condition with time period of 1, 2, 3, 4, 5, 6 or 7 minutes after fire condition is registered.

   + Option for ‘LOGICAL AND’ realization of two fire alarm lines.

   + Duty Mode condition with direct activation of Fire Condition 2nd Stage ” for two fire alarm lines.

   + Status Indication of the device for data transmission RS485.

   + Option for switching on/off interface RS485 communication.

   + Built-in sounder for fire condition – one tonal, continuous, can be switched off.

   + Built-in sounder for fault condition – one tonal, discontinuous, can be switched off.

   + Test mode for fire alarm lines.

   + Disabling fire alarm lines.

   + Disabling outputs for fire condition.

   + Expanding the options by means of extra relay outputs for fire condition for each line and built-in RS485 for operation in a local network.

   + Input for remote Reset fires operation.

– Indications of registered events:

   + Light indication: LED.

   + Sound: Built-in buzzer.

– Power supply:

   + Voltage: (100-240)VAC.

   + Frequency: 50/60 Hz.

– Backup batteries:

   + Battery type: lead, gel electrolyte.

   + Number of batteries: 2 pcs.

   + Nominal voltage of the backup battery: 12V.

   + Nominal capacity C20: (7,0) Ah.

   + Charge voltage: 28VDC.

– Operation in Duty mode upon interruption in main power supply:

   + Lines – 24V/ 1,2Ah – 24V/ 4,5Ah – 24V/ 7,0Ah.

   + 4 lines – 24 h – 98 h – 140 h.

– Consumption on backup batteries supply:

   + Configuration of 4 lines: < 45 mA at 24V DC.

– Power supply to external devices:

   + Voltage: (19-27)VDC.

   + Maximum current value (including current of contr.outputs): 1,2A.

– Fuses:

  + Main supply 230V: 4.0 A.

  + Backup battery: 6.0 A.

  + Power supply to external devices: 1.85 A automatic.

  + Monitored outputs: 1.1 A automatic.

– Dimension: 304mm x 222mm x 94mm.

– Weight (backup batteries not included): 0.98 kg.

– Bảo hành: 12 tháng.