Trung tâm báo cháy địa chỉ 8 loop GST GST-IFP8

Chat Zalo hoặc Gọi ngay 0984 104 365 để được tư vấn giá tốt!

Liên hệ

Trung tâm báo cháy địa chỉ 8 loop GST GST-IFP8

– Listed to LPCB.

– 8 x Loops (242) capacity (1936) addressable points.

– Maximum 10 Loops Standalone.

– Modular constructed for future expansion.

– 40 x15 lines Colour Graphical LCD Display.

– Up to 999 programmable zones and 140 zone indication.

– Auto Programming Day and Night Mode.

– Enable and Disable function.

– PAS and Acknowledge Function.

– Dirty Detector Reporting.

– Duplicate Address Checking.

– Device Mismatch.

– Walk Test Function with optional silent.

– Can edit device detailed and programmed.

– Programmable form PC or Panel.

– History record-999 fire incident only and 999 event capacity in non-volatile memory Fully simulation of Cause and Effect.

– Advanced user friendly programming software including ‘Fuzzy Logic’.

– Networked with all GST Intelligent Fire panels up to 99 Nodes, Optional Fiber Optic and LAN Network Interface.

– RS 485 mimic and repeater output up 64.

– RS 232-USB CRT interface, including GSTGMC graphic.

– Built in Fire Alarm, FPE, Fault and Alarm Router output

– Panel Printer included.

– Built in Battery charger mode.

Thông số kỹ thuật

– Standard: EN54 Part 2/4; BS5839 Part 4.

– Approvals: LPCB.

– Main Input Voltage: 220 ± 10% VAC 50/60Hz.

– Input Current Rating: 1Amphere.

– System Operating Voltage: 24 VDC Nominal (20-27 VDC).

– Loop Capacity: Loop 10:242- Address per loop.

– Loop Length: 

   + 1.00mm²-800M-Full Load;

   + 1.5mm²-1.2Km-Full Load;

   + 2.0mm²-1.5Km-Half Load.

– Loop Topology: Class A and Class B.

– Zone Capacity: 999 Zones programmable.

– Sounder Circuits: 

   + Fire Routing: 200mA /24Vdc/4.7KΩ EOLR;

   + F.P.E. Output: 500mA /24Vdc/4.7KΩ EOLR;

   + Sounder Circuit Output: 1A /24Vdc/4.7KΩ EOLR;

   + Dry Contact: Optional C-9302 module.

– Fuses: 

   + Mains 2A (20mm A/S ceramic);

   + Battery: 2A (20mm A/S HRC ceramic).

– Common Fault Relay Output: Volt-free changeover 1.0A at 24 VDC.

– 24 VDC Fused Output: Maximum load 500mA at 17-28VDC.

– Standby Batteries: Twin 12 Vdc Bat; 38AH.

– Battery Charging Current Limit: 2A/24VDC.

– Bảo hành: 12 tháng.